FX-1/FX-1R Maintenance Manual
4-3. Replacing the OCC Coaxial/Angle Light Board Assemblies
(1) Detach the light assembly from the XM base using the procedure described in section 4-1,
Replacing the OCC Assembly.
(2) Remove the SEMS cap bolts to replace the OCC coaxial light board assembly.
(3) Remove the SEMS cap bolts to replace the OCC angle light board assembly.
(4) Reassemble the components in the reverse order of disassembly.
(5) After the OCC light board has been replaced, it is necessary to adjust the OCC light. (See 4-7,
List of Readjustment Items After Replacement.)
Figure 4-3-1 Replacing the OCC Coaxial/Angle Light Board Assembly
ngle light board
assembly
SEMS cap
bolts (× 2)
Coaxial light
board assembly
SEMS cap bolts
(× 4)
4-3
Rev. 2.00