FX-1/FX-1R Maintenance Manual
4-6. Adjusting the OCC Light Quantity
<Procedure>
Check that the OCC light goes on with manual control.
Carry out "Adjustment of OCC Light" in the MS parameters. (See the section related to OCC
light quantity adjustment in the specifications for the MS parameter operation.)
4-7. List of Readjustment Items After Replacement
Table 4-7-1 List of Readjustment Items after Replacement
Camera
assembly
Light assembly
CCD camera
lens
Light board
assembly
Light filter
Focus adjustment
○ ― ○ ― ―
Filter adjustment
△ ○ △ ― ○
Light adjustment
△ ○ △ ○ ○
Origin coarse adjustment
(Note)
○ ― ○ ― ―
OCC offset (Note)
○ ― ○ ― ―
Head offset (Note)
○ ― ○ ― ―
BMR offset (Note)
○ ― ○ ― ―
HMS offset (Note)
○ ― ○ ― ―
○: Mandatory
△: Check
−: Unnecessary
(Note) See the specifications for the MS parameter operation.
CAUTION
To prevent personal injury, do not put your hand inside the machine
or your face or head close to the machine during operation of the
HOD.
4-6
Rev. 2.00