2018-10-11 15:55:58 UTC Major Fan Tray 3 Failure
2018-10-11 15:55:58 UTC Major Fan Tray 4 Failure
RELATED DOCUMENTATION
Maintaining QFX5200 Cooling System | 127
QFX5200 Power System
IN THIS SECTION
QFX5200 AC Power Supply Descripon | 39
QFX5200 AC Power Specicaons | 42
QFX5200 Power Cord Specicaons | 43
QFX5200 AC Power Supply LEDs | 45
QFX5200 DC Power Supply Descripon | 48
QFX5200 DC Power Specicaons | 51
QFX5200 DC Power Supply LEDs | 52
QFX5200 AC Power Supply Descripon
The two power supplies in QFX5200 are hot-removable and hot-insertable eld-replaceable units
(FRUs). The power supplies are installed in the switch at the factory. You can install replacement power
supplies from the management panel without powering o the switch or disrupng the switching
funcon. QFX5200 switches can operate with one PSU, but two power supplies are required to run
without error messages and to have redundancy. See Figure 23 on page 40 and Figure 24 on page 40
for examples of QFX5200 AC power supplies.
The AC power supply in QFX5200-32C and QFX5200-32C-L switches is 850 W; the AC power supply
in QFX5200-48Y switches is 650 W. Be sure to use the correct power supply for your chassis product
SKU (see Table 17 on page 41).