NOTE: The services gateway must be connected to earth ground during
normal operation. The protective earthing terminal on the rear of the chassis
is provided to connect the services gateway to ground.
CAUTION: We recommend using a surge protector for the power connection.
NOTE: Use the cable tie holder to secure the power cord on to the power
supply point.
NOTE: We strongly recommend that you use only the 3-prong power cord
supplied with your services gateway. If you are using a 2-prong power cord,
then ensure that your services gateway is adequately grounded using the
grounding point available on the back panel of the chassis.
Related
Documentation
Installing the SRX240 Services Gateway on page 53•
• Required Tools and Parts for Installing and Maintaining the SRX240 Services Gateway
on page 48
• Connecting and Organizing Interface Cables to the SRX240 Services Gateway on
page 63
• Grounding the SRX240 Services Gateway on page 60
• Powering On and Powering Off the SRX240 Services Gateway on page 74
Connecting the SRX240 Services Gateway DC Power Supply Model to a DC Power
Source
WARNING: DC-powered SRX240 Services Gateways are intended for
installation only in a restricted access location.
WARNING: Before performing the following procedure, ensure that power is
removed from the DC circuit. To ensure that all power is off, locate the circuit
breaker on the panel board that services the DC circuit, switch the circuit
breaker to the off position, and tape the switch handle of the circuit breaker
in the off position.