Functional Description Analog In- and Outputs
2106
Name: Basis
KEB COMBIVERT F5
Chapter Section Page Date
04.05.04
© KEB Antriebstechnik, 2002
All rights reserved
6.2.10 Brief Description
Analog Outputs
The KEB COMBIVERT has three programmable analog outputs (ANOUT1...4). Para-
meters An.31 and An.36 allow the selection of one size each which is given out at the
outputs X2A.5 / 6. The third and fourth analog output (An.41/47) is not led to the
terminal strip, it can be output as switching condition 42, e.g. 43 with the digital outputs
as PMW-signal. By means of the characteristic amplifier (An.33...35 / 38...40 / 43...45/
49...51) the analog signals can be adapted to the requirements. The ru-parameters
show the current size before and after the amplification. The period time for the PWM-
signal can be adjusted with An.46/52.
Fig. 6.2.10 Principle of analog output
An.31
An.33
An.34
An.35
X2A.5
ANOUT1
X2A.8
AGND
0...±100%
0...±10V
ru.34ru.33
An.36
An.38
An.39
An.40
X2A.6
ANOUT2
X2A.9
AGND
0...±100%
0...±10V
ru.36ru.35
An.41
An.43
An.44
An.45
PWM
100%
An.46
An.47
An.49
An.50
An.51
PWM
100%
An.52
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
ru.7
ru.1
±ru.7
±ru.1
ru.20
ru.18
ru.15
ru.17
An.xx
±ru.52
ru.52
ru.17
ru.38
ru.46
±ru.12
ru.12
±ru.11
ru.11
-
±ru.2
ru.2
Observe the different functional range of the
hard- and software of the different control
cards !
The reference values of real and set values
depends on ud.2.
100% correspond to An.31/36/41/47 =
absolute actual value (100 Hz/1000 min
-1
)
absolute set value (100 Hz/±1000 min
-1
)
actual value (±100 Hz/±1000 min
-1
)
set value (±100 Hz/±1000 min
-1
)
output voltage (500 V)
DC voltage (1000 V)
apparent current (2 * I
rated
)
active current (2 * ±I
rated
)
digital An.32/37/42/48
external PID output (±100 %)
absolute ext. PID output (100 %)
absolute active current (2 è I
rated
)
Power mod. temperature (100 C)
Motor temperature (100 C)
actual torque (F5-M/S)
absolute actual torque (F5-M/S)
set torque (F5-M/S)
absolute set torque (F5-M/S)
system deviation/speed controller (±100Hz/±1000min
-1
)
speed reference variable (±100 Hz/±1000 min
-1
)
absolute speed reference variable (100 Hz/1000 min
-1
)
do.0...do.7
value Ñ42ì
do.0...do.7
value Ñ43ì

Table of Contents

Other manuals for KEB COMBIVERT F5 Servo

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 Servo and is the answer not in the manual?

KEB COMBIVERT F5 Servo Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F5 Servo
CategoryDC Drives
LanguageEnglish

Related product manuals