KEB COMBIVERT F5
Name: Basis
05.05.04
6
Section PageDate
© KEB Antriebstechnik,2002
All rights reserved
Chapter
Functional DescriptionParameter Sets
Fig. 6.8.7 Principle of parameter set selection
6.8.7 Parameter Set
Selection
Fr.2
0
1
2
3
2
0
2
1
2
2
1234567 1234567
4
5
digital
As shown in Fig. 6.8.7, with Fr.2 it is defined whether the parameter set selection is
enabled or disabled via keyboard/Bus (Fr.4), the terminal strip or via control word
(SY.50). The selection is activated with „Enter“.
Fr.2 Function
0 Set selection deactivated; set 0 always active
1 Set selection via keyboard/Bus with Fr.4
2 Set selection binary-coded via terminal strip
3 Set selection input-coded via terminal strip
Priority: ST>RST>R>F>I1>I2>I3>I4>IA>IB>IC>ID
4 Set selection input-coded via terminal strip
Priority: ID>IC>IB>IA>I4>I3>I2>I1>R>F>RST>ST
5 Set selection via control word SY.50
Fr.2 Source parameter set
Fr.4 Adjustment parameter set
This parameter can be written by Bus as well as by keyboard. The desired parameter
set (0...7) is preadjusted directly as value and activated with „Enter“.
set selection
deactivated
always set 0 activ
Fr.4 via
keyboard / bus
terminal strip
binary coded
terminal strip
input coded
ST>RST...>ID
terminal strip
input coded
ID>IC...>ST
Sy.50 with
control word
(only bus)
Parameter set 0...7
Fr.3 Parameter set lock
Set 0...7 (Value 0...255)
Is
selected set
locked?
Error message
E.SEt
yes
no
Actual Parameter set
Attention! The valency at
Fr.2 = 2...4 is generally ID >
IC > ...>ST. The succession
describes at the inputs refers
to the priority.