6
57
KEB COMBIVERT F5
Name: Basis
04.05.04
6
Section PageDate
© KEB Antriebstechnik, 2002
All rights reserved
Chapter
Functional DescriptionU/f-Characteristic Adjustment
ud.2 0802h - - 0 11 1 0/4/8 default value dep. on ud.2
uF.0 0500h ✔✔- 0 Hz 400 Hz 0,0125 Hz 50,0 Hz depending on ud.2
uF.1 0501h ✔✔- 0,0 % 25,5 % 0,1 % 2,0 % -
uF.2 0502h ✔✔- -0,0125 Hz 400 Hz 0,0125 Hz 0,0 Hz dep. on ud.2; -0,0125 = parabolic
uF.3 0503h ✔✔- 0,0 % 100,0 % 0,1 % 0,0 % -
uF.4 0504h ✔✔- 0,0 % 25,5 % 0,1 % 0,0 % -
uF.5 0505h ✔✔- 0,00 s 10,00 s 0,01 s 0,00 s -
uF.9 0509h ✔✔- 1 V 649 V; 650: off 1 V 650:off -
uF.10 050Ah ✔✔-0 3 1 0-
uF.11 050Bh ✔✔- 0 PU-Id 1 PU-Id PU-Id: Power unit Identification
uF.19 0513h -- 0 10 1 0 -
Param. Adr.
min
max
default
ENTER
PROG.
R/W
Step
6.5.8 Used Parameters
small switching frequency
- less inverter heating
- less discharge current
- fewer switching losses
- fewer radio interferences
- improved concentricity at small
speeds
high switching frequency
- less noise development
- improved sine-wave simulation
- less motor losses
Influences and effects of the switching frequency are listed below:

Table of Contents

Other manuals for KEB COMBIVERT F5 Servo

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 Servo and is the answer not in the manual?

KEB COMBIVERT F5 Servo Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F5 Servo
CategoryDC Drives
LanguageEnglish

Related product manuals