6
6
13
KEB COMBIVERT F5-M / S
Name: Basis
12.05.04
Section PageDate
© KEB Antriebstechnik, 2002
All Rights reserved
Chapter
Functional DesriptionOperating and Unit Data
6.1.1 Summary of
ru-Parameter
6.1 Operating and
Unit Data
The parameter groups Ñruì, ÑInì and ÑSyì are described in this chapter. They serve for
the operational monitoring, error analysis and evaluation as well as for the unit
identification.
6. Functional Description
The ru- (run) parameter group represents the multimeter of the inverter. Speeds, currents,
voltages etc. are displayed, which allow a conclusion on the operating condition of the
drive. This can be especially helpful for the start-up of a plant or with regard to trouble
shooting. Following parameters are available:
ru. 0 inverter state
ru. 1 set value display
ru. 2 ramp output display
ru. 3 actual frequency display
ru. 7 actual value display
ru. 9 encoder 1 speed
ru. 10 encoder 2 speed
ru. 11 set torque display
ru. 12 actual torque display
ru. 13 actual utilization
ru. 14 peak utilization
ru. 15 apparent current
ru. 16 peak apparent current
ru. 17 active current
ru. 18 actual DC voltage
ru. 19 peak DC voltage
ru. 20 output voltage
ru. 21 input terminal state
ru. 22 internal input state
ru. 23 output condition state
ru. 24 state of output flags
ru. 25 output terminal state
ru. 26 active parameter set
ru. 27 AN1 pre amplifier disp.
ru. 28 AN1 post amplifier disp.
ru. 29 AN2 pre amplifier disp.
ru. 30 AN2 post amplifier disp.
ru. 31 AN3 pre amplifier disp.
ru. 32 AN3 post amplifier disp.
ru. 33 ANOUT1 pre ampl. disp.
ru. 34 ANOUT1 post ampl. disp.
ru. 35 ANOUT2 pre ampl. disp.
ru. 36 ANOUT2 post ampl. disp.
ru. 37 motorpoti actual value
ru. 38 power module temperature
ru. 39 OL counter display
ru. 40 power on counter
ru. 41 modulation on counter
ru. 42 modulation grade
ru. 43 timer 1 display
ru. 44 timer 2 display
ru. 45 act. carrier frequency
ru. 46 motor temperature
ru. 47 act.torque limit mot.
ru. 48 act.torque limit gen.
ru. 49 actual ref. torque
ru. 52 ext. PID out disp.
ru. 53 AUX display
ru. 54 actual position
ru. 56 set positon
ru. 58 angular difference
ru. 59 rotor adaption factor
ru. 60 Actual position index
ru. 61 target position
ru. 63 profil speed
ru. 68 rated DC voltage
ru. 69 distance ref.-zeropoint
ru. 71 teach/scan position
ru. 73 relative set torque
ru. 74 relative active torque
ru. 78 relative active value display
ru. 79 absolute speed value (EMK)
ru. 80 digital output state
ru. 81 active power

Table of Contents

Other manuals for KEB COMBIVERT F5 Servo

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 Servo and is the answer not in the manual?

KEB COMBIVERT F5 Servo Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F5 Servo
CategoryDC Drives
LanguageEnglish

Related product manuals