6
4
KEB COMBIVERT F5-M / S12
Name: Basis
12.05.04
Chapter Section Page Date
© KEB Antriebstechnik, 2002
All Rights reserved
Functional Desription Setpoint- and Ramp Adjustment
4000
oP.7*
1
(oP.6)
oP.6
oP.14
oP.10
oP.15*
1
(oP.14)
oP.11*
1
(oP.10)
+100
-100
-4000
6.4.5 Setpoint Limits
Absolute maximal
value reverse
Following limit values can be preadjusted:
Setpoint[%]
Setpoint[%]
Minimal value
forward
Maximal value
forward
Absolute maximal
value forward
Maximal value
reverse
Minimal value
reverse
*1 If the value ÑForì is adjusted in these parameters (limit values rotation direction
reverse), then the adjusted values for rotation direction forward (oP.6, oP.10
and oP.14) are valid.
In case of setpoint adjustment in percent the minimal and maximal values form the
characteristic for the setpoint calculation (0% = minimal value; 100% = maximal
value). In case of absolute setpoint adjustment the minimal and maximal values
limit the setpoint. Separate limits can be adjusted for both directions of rotation. If
the value ÑForì is adjusted for rotation direction ÑReverseì, then the values for
ÑForwardì are valid.
Setting range: oP.6 = 0...4000 rpm Standard = 0 rpm
oP.10 = 0...4000 rpm Standard = 2100 rpm
oP.7 = For, 0...4000 rpm Standard = For
oP.11 = For, 0...4000 rpm Standard = For
Minimal- / Maximal value
(oP.6, oP.7, oP.10, oP.11)
After the minimal and maximal values the setpoint is limited through the absolute
maximal value and subsequently transferred to the ramp generator. Since the ana-
log setpoint is always calculated onto the maximal values (oP.10, oP.11), it is
possible, to adjust the characteristic of the analog setpoint with the same gain for
both directions of rotations (see Fig. 6.4.5.a) in spite of different maximal output
speeds. If the value ÑForì is adjusted in oP.15, then the absolute maximal speed of
oP.14 is valid for both directions of rotation.
Absolute maximal value
(oP.14, oP.15)
Fig. 6.4.5 Setpoint limits

Table of Contents

Other manuals for KEB COMBIVERT F5 Servo

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 Servo and is the answer not in the manual?

KEB COMBIVERT F5 Servo Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F5 Servo
CategoryDC Drives
LanguageEnglish

Related product manuals