6 7
KEB COMBIVERT F5
18
Name: Basis
04.05.04
Chapter Section Page Date
© KEB Antriebstechnik, 2002
All rights reserved
Functional Description Protective Functions
Param. Adr.
min
max
default
ENTER
PROG.
R/W
Step
Used Parameters
fr. 8 0908h ✔✔- 0 7 1 0 not at F5-S
Pn.12 040Ch -- 0 7 1 7 -
Pn.13 040Dh - - 0 120 s 1 s 0 s -
Pn.14 040Eh -- 0 6 1 6 -
Pn.15 040Fh - - 0 % 100 % 1 % 100 % only at F5-S
dr.11 060Bh ✔✔- 0 1 1 1 not at F5-S
dr.12 060Ch ✔✔- 0,0 710,0A 0,1A LTK not at F5-S
dr.34 0622 - - 0,1 s 10,0 s 0,1 s 0,5 s only at F5-S
dr.35 0623 - - 0,1 s 10,0 s 0,1 s 0,2 s only at F5-S
dr.36 0624 - - 0,1 s 10,0 s 0,1 s 5,0 s only at F5-S
ru.15 020Fh - - - 0,0 A 6553,5 A 0,1 A - -
The KEB COMBIVERT provides another possibilitiy to protect the motor by connecting
an external temperature monitoring. Following components can be connected to
terminals T1/T2:
External error control
procedure
Thermo contact
(NC contact)
Temperature sensor (PTC)
1650...4k tripping resistance
750...1650 reset resistance
T1
T2
T1
T2
With these two parameters the behaviour of the terminals T1/T2 is determined. The
function is described in Chapter 6.7.6.
dOH stopping mode (Pn.12)
dOH delay time (Pn.13)

Table of Contents

Other manuals for KEB COMBIVERT F5 Servo

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KEB COMBIVERT F5 Servo and is the answer not in the manual?

KEB COMBIVERT F5 Servo Specifications

General IconGeneral
BrandKEB
ModelCOMBIVERT F5 Servo
CategoryDC Drives
LanguageEnglish

Related product manuals