CANopen
6 Parameter setting
6-22
L
BA2175 EN 2.0
6.3.5 Process-data assignment for 93XX
With 93XX controllers, the process data assignment can be changed by reconfiguring the function
blocks AIF-IN and AIF-OUT.
Process data telegram to
drive
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8
Control w ord
Low byte
Control w ord
High byte
AIF-IN.W1
Low byte
AIF-IN.W1
High byte
AIF-IN.W2
Low byte
AIF-IN.W2
High byte
AIF-IN.W3
Low byte
AIF-IN.W3
High byte
Control word: see chapter 6.3.5.1.
AIF-IN.W1 to AIF-IN.W3 depend on the signal configuration selected under L-C0005.
For detailed description of the 93XX signal configuration see the Operating Instructions for 93XX
(only the main configurations: 1000, 4000, 5000, etc.) or the Manual for 93XX.
Other controller signals can be assigned to AIF-IN.W1 to AIF-IN.W3. For this, the function-block
configuration - described in the 93XX Manual - is used. The AIF-IN function block determines the
input data of the controller as data interface for the 2175 fieldbus module.
For more detailed information about the AIF-IN function block, see the 93XX Manual.
Signal configuration (L-C0005) AIF-IN.W1 AIF-IN.W2 AIF-IN.W3 AIF-IN.D1
Speed control 1003 / 1013 /
1113
NSET-N
Speed setpoint
100 % = 16383
Torque control 4003 / 4013 /
4113
MCTRL-MADD
Torque setpoint
100 % = 16383
not assigned
DF master 5003 / 5013 /
5113
NSET-N
Speed setpoint
100 % = 16383
DF slave bus 6003 / 6013 /
6113
DFSET-A-TRIM
Phase t rimming
DFSET-N-TRIM
Speed trimming
n
o
t
a
s
s
i
g
n
e
d
n
o
t
a
s
s
i
g
n
e
d
DF slave cascade 7003 / 7013 /
7113
DFSET-VP-DIV
DF factor
DFSET-A-TRIM
Phase t rimming
not assigned not assigned
Cam profiler 1xxx3 YSET1-FACT
Positioning 2xxx3 not assigned
vector control 1xx3 / 2xx3 / 3xx3
/ 5xx3 / 100x3
NLIM-IN1
not assigned
vector control 4xx3 NCTRL-MADD
vector control 6xx3 DFSET-A-TRIM DFSET-N-TRIM
vector control 7xx3 / 8xx3 / 9xx3 DFSET-VP-DIV DFSET-A-TRIM
vector control 100x3 NLIM-IN1
n
o
t
a
s
s
i
g
n
e
d
vector control 110x3 not assigned
not ass
i
gne
d
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: info@actechdrives.com
Show/Hide Bookmarks

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 2175 and is the answer not in the manual?

Lenze 2175 Specifications

General IconGeneral
BrandLenze
Model2175
CategoryNetwork Hardware
LanguageEnglish