Technical Information
135
G 1xxx/G 2xxx
Cause:
Incorrect positioning of adjustable door lock latch prevents the door contact
switch from closing.
Remedy:
Reset the adjustable door lock latch.
Cause:
Door seal incorrectly seated, preventing the door contact switch from closing.
Remedy:
Check the door seal seating and adjust as necessary.
Cause:
Connections between the electronic module and the door contact switch are
open-circuited.
Remedy:
1. Check the connection wires for continuity.
2. Replace plugs and wires, if necessary.
3.4 Program Interrupted, No Fault Indication
Symptom:
Program interrupted suddenly. No fault is indicated by the LEDs. No fault is
registered in the fault memory.
Cause:
Incorrect positioning of adjustable door lock latch prevents the door contact
switch from closing.
Remedy:
Reset the adjustable door lock latch.
Cause:
Door seal incorrectly seated, preventing the door contact switch from closing.
Remedy:
Check the door seal seating and adjust as necessary.
3.5 Diagnostic Support Cannot Establish a Connection
Symptom:
The connection cannot be made via the optical interface.
Cause:
Diagnosis support cannot be used with a machine logged onto RemoteVision.
Remedy:
Access the service mode or briefly disconnect the machine from the power
supply or log off the machine from the RemoteVision system.
Subsequently, diagnostic support can be connected to the machine via the
optical interface. RemoteVision cannot be used while this connection is in
place.
To deactivate the optical interface again, depending on the selected
remedy: