Technical Information
60
G 1xxx/G 2xxx
1. Open the door.
2. Loosen the flat round screw.
3. Adjust the locking plate as necessary.
4. Tighten the screw.
Note:
Adjust the locking plate so that the door seal is not excessively crushed and
not under excess pressure when the door is closed (see Figure 020-12, Item
A). The locking plate can be adjusted by 1 millimeter in either direction.
Figure 020-12: Door Seal with Door
4.4 Bottom Door Seal Removal
1. Remove the cable holder. See Section 020-4.2.
2. Remove the door seal.
Note:
When re-installing the door seal, ensure that the seal holder is reseated in
the U-shaped slot in the door inner panel. See Figure 020-13.