Programming
143
7. Hysteresis
Temperature difference between heating switch-on-and switch-off
points.
Choose from the following options:
– Normal (Off 0°C, On -6°C)
– Low (Off +3°C, On 0°C)
– User defined
+3°C to –10°C in 1°C increments
8 .Warm up
Heating-up speed, how rapidly the water should heat up.
Warm up is locked if "No" is programmed in program stage 4.
Heating.
Choose from the following options:
– No
– 1°C/min to 10°C/min
Heating is permanently activated as required.
9. Level 1
In the programme header, the fill type can be selected between
automatic load adjustment, water level, the water quantity and the
suds ratio. With automatic load adjustment or water level, level1 can
be adjusted accordingly.
Choose from the following options:
– Water quantity
Setting in 0.5 l increments from 0lto999l.
– Water level
Setting in 2mm increments from 0mm to 350mm.
– Laundry to suds ratio
Setting in 0.5 kg increments from 1:0.0kg/l to 1:20kg/l.
10. Water inlet 1
Control of water intake valves
Choose from the following options:
– Automatic
With the "automatic" setting the water intake valves are activated
such that the required temperature for the wash cycle is already
reached from the first intake of water by alternately activating cold or
hot water valves.