Optional modules
48
Commissioning the dispenser pumps
Before the liquid dispenser pumps can be used, the liquid detergent
must be drawn into the system and the amount to be dispensed set.
Dispenser calibration
Dispenser calibration is used to measure the throughput of individual
dispenser pumps.
To go directly to
"dispenser
calibration" when
the machine is
switched off:
Press and hold multifunction button2 and switch the machine on
with "Power On".
Dispenser calibration
Main menu
Dispenser pump 1
Dispenser pump 2
Options:
– Dispenser pump 1to13
Select a dispenser pump.
When a dispenser pump is selected, the following will appear in the
display:
Dispenser calibration
Dispenser pump 1
100 ml
0/1
0t: P: NoV: s
Useful tip: The dispensing amount can be set from 0 to 9999ml in
1ml increments.
Press multifunction button0/1.
The dispensing hose will fill up.
Stop the process by pressing button0/1.
Run the hose of the dispenser pump that is being checked upwards
into a measuring vessel.
Irritant detergents!
Can cause skin and eye irritation.
Avoid contact with skin and eyes, wear protective clothing.
Return to the main menu by pressing "Back".
Dispenser calibration
Main menu
Dispenser pump 1
Dispenser pump 2
Select a dispenser pump.