1 Introduction
1.3 System Configuration
15
FX Configurator-FP
Operation Manual
1
Introduction
2
Install
Uninstall
Start&Exit
3
Window and
Operation
Config
4
Creating
Files
5
Data set
6
Setting
The
Connection
7
Data flow
And
Procedure
8
Debug
In the
Positioning
9
Print
10
Edit
Function
In data
Cautions on communication setting
Do not change the communication settings for outside modules via parameters or sequence program.
If changed, a communication error occurs between FX Configurator-FP and PLC (20SSC-H).
4) Check that the format of the communication connector to be used is correct.
(D8120, D8400, D8420 = K0)
Also, with peripheral devices, check that parameters for communication setting are correct.
How to check parameters with GX Developer
A check mark to [Operate communication setting] on [PLC system (2)] tab in [PLC parameter] of GX
Developer disables the communication through the selected port between FX Configurator-FP and
PLC(20SSC-H). When the communication fails, write the parameter that clears the check box [Operate
communication setting] to the PLC via the built-in dedicated programming connector with GX Developer.
When the PLC type of the project is the
FX3U(C), the channel specification (CH1/
CH2) combo box appears. When using
the FX
3U-422-BD, FX3U-232-BD, FX3U-
USB-BD or the first FX
3U-232ADP
connected to the FX
3U-CNV-BD, set CH1
and check the settings.
When using the FX
3U-232ADP connected
to other than the FX
3U-CNV-BD or the
second FX
3U-232ADP connected to the
FX
3U-CNV-BD, set CH2 and check the
settings.
5) Check that RS and RS2 instructions are not programmed for the corresponding communication
connector.
Do not execute RS and RS2 instructions in this case.
6) When an inverter communication instruction is programmed for the corresponding communication
connector, delete the instruction first, and reboot the PLC's power.
2. Connection via Ethernet adapter [Supported Ver. 1.70 or later]
This subsection shows the system configurations for Connection via Ethernet adapter from the Ethernet port
in the personal computer.
FX Configurator-FP
FX
3U
/FX
3UC
FX
3U
-20SSC-H
Direct connection to Ethernet adapter via Ethernet
FX
3U
-ENET-ADP

Table of Contents

Other manuals for Mitsubishi FX3U Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi FX3U Series and is the answer not in the manual?

Mitsubishi FX3U Series Specifications

General IconGeneral
BrandMitsubishi
ModelFX3U Series
CategoryController
LanguageEnglish

Related product manuals