53
FX Configurator-FP
Operation Manual
1
Introduction
2
Install
Uninstall
Start&Exit
3
Window and
Operation
Config
4
Creating
Files
5
Data set
6
Setting
The
Connection
7
Data flow
And
Procedure
8
Debug
In the
Positioning
9
Print
10
Edit
Function
In data
7 Read / Write / Verify / Initialize
7.1 Data type and storage location
7. Read / Write / Verify / Initialize
Reading, Writing and Verifying the data (positioning parameters, servo parameters and table information) for
each axis, and initializing the 20SSC-H.
Caution
When reading or writing data, use the FX Configurator-FP version that is the same as or later than the
FX Configurator-FP used to write data to the 20SSC-H.
Using FX Configurator-FP of earlier version may clear the setting data or change the setting data to invalid
values.
7.1 Data type and storage location
1. Data type and Description
Data type Description Storage location
Positioning
parameters
The parameters required for positioning control.
For positioning parameters details, Refer to
FX3U-20SSC-H User's
manual.
For setting procedures of positioning parameters, refer to
Section 5.2.
• Positioning parameters for X-axis.
• Positioning parameters for Y-axis
• The BFM in 20SSC-H
• Flash ROM in 20SSC-H
Servo
parameters
The parameters of servo amp. 20SSC-H transfers servo parameters to
servo amps via SSCNET at power on.
For servo parameters details, refer to the manual of the
servo amp to be used.
For setting procedures of servo parameters, refer to Section 5.3.
• Servo parameters for X-axis.
• Servo parameters for Y-axis
• The BFM in 20SSC-H
• Flash ROM in 20SSC-H
Table
information
The data for table operation.
• Table information for X-axis.
• Table information for Y-axis.
• Table information for XY-axis.
• The BFM in 20SSC-H
• Flash ROM in 20SSC-H