8 Debug in the positioning
8.2 Testing the Operation
73
FX Configurator-FP
Operation Manual
1
Introduction
2
Install
Uninstall
Start&Exit
3
Window and
Operation
Config
4
Creating
Files
5
Data set
6
Setting
The
Connection
7
Data flow
And
Procedure
8
Debug
In the
Positioning
9
Print
10
Edit
Function
In data
8.2 Testing the Operation
Testing each operation in the position start, Feed present value change, velocity change, zero return, JOG
and MPG, switching the 20SSC-H into the test mode while operation monitoring.
8.2.1 Switching into test mode
Switching into FX Configurator-FP into test mode.
1 Follow any of the procedures below.
Click [Test On/Off].
Select [Online] [Test] [Test On/Off].
FX Configurator-FP switches into test mode.
When switching test mode into monitor mode
1) Follow any of the procedures below when switching the test mode into monitor mode.
- Click [Test On/Off].
- Select [Online] [Test] [Test On/Off].
2) FX Configurator-FP starts monitoring
STARTUP AND MAINTENANCE
PRECAUTIONS
Do not touch any terminal while the PLC's power is on.
Doing so may cause electrical shock or malfunctions.
Before cleaning or retightening terminals, externally cut off all phases of the power supply.
Failure to do so may expose you to shock hazard.
Before modifying the program under operation or performing operation for forcible output, running or stopping,
carefully read the manual, and sufficiently ensure the safety.
An operation error may damage the machine or cause accidents.
To test Zero-return, JOG operation and Positioning data, throughly read this manual, ensure the safe system
operation
An operation error may damage the machine or cause accidents.
The response, such as the JOG operation, may be slow according to the running state of the personal computer at
the time of the test operation. In the test operation, the PLC performance can be slower due to the busy state of
personal computer.
- End all other applications running except FX Configurator-FP.
- At destination specification (refer to chapter 6), set the transmission speed at 38.4kbps or higher.

Table of Contents

Other manuals for Mitsubishi FX3U Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi FX3U Series and is the answer not in the manual?

Mitsubishi FX3U Series Specifications

General IconGeneral
BrandMitsubishi
ModelFX3U Series
CategoryController
LanguageEnglish

Related product manuals