8 Debug in the positioning
8.2 Testing the Operation
74
FX Configurator-FP
Operation Manual
8.2.2 Operation test in the positioning (except JOG/MPG)
Testing the operation in the 20SSC-H positioning (except into JOG/MPG) by test mode.
For the procedure to switch into test mode, refer to Subsection 8.2.1.
1 Follow any of the procedures below when switching the test mode into
monitor mode.
• Click [Operation test X-axis] / [Operation test Y-axis].
• Select [Online] [Test] [Operation test] [Operation test X-axis] / [Operation test Y-axis].
The position start tab in [Operation test X-axis] / [Operation test Y-axis] dialog box appears.
For Feed present value CHG tab, refer to Subsection 8.2.3.
For velocity change tab, refer to Subsection 8.2.4.
For zero return tab, refer to Subsection 8.2.5.
For JOG/MPG tab, refer to Subsection 8.2.6.
2 Set the items below.
Item Description
Monitor item
Displays present address, Operation speed present value, status information and Error
code
Present address
Displays the present address [Unit : User unit
*1
]
Operation speed present
value
Displays the operation speed present value [Unit : User unit
*1
]
READY/BUSY
Displays status information
• READY : ON
• BUSY : OFF
Table No. being
executed
Displays X/Y-axis table No. in execution
It is blank here at other than table operation
Error code
Displays error codes
Displays 0 with no error