7 Read / Write / Verify / Initialize
7.3 Writing [positioning/servo parameters and table information]
7.3 Writing [positioning/servo parameters and table information]
Data writing procedures comprise of [Write to module] and [Flash ROM write].
7.3.1 Writing to the BFM
Writing [positioning parameters, servo parameters table information] to the 20SSC-H BFM.
1 Operate any of the following procedures
• Click [Write to module].
• Select [Online] [Write to module].
[Write to module] dialog box appears.
2 Select the data to be written.
*1. For the flash ROM write, refer to the following.
For the flash ROM write, refer to Subsection 7.3.2.
3 Click <OK>.
FX Configurator-FP writes the selected data to the 20SSC-H BFM.
For the displayed messages, refer to Section 7.6.
Item Description
COM port Displays [COM port] in [Connection setup] dialog box
Transmission speed Displays [Transmission speed] in [Connection setup] dialog box
Module No. Displays [Module No.] in [Connection setup] dialog box
Item Ticks off the data to be read
Positioning parameters
Ticks off the axis of positioning parameters to be written
•X-axis
•Y-axis
Servo parameters
Ticks off the axis of servo parameters to be written
•X-axis
•Y-axis
Table information
Sets the writing range after ticking off the axis of table information to be written
Setting range : 0 to 299
•X-axis
•Y-axis
•XY-axis
Flash ROM write*
1
Ticks off when writing the data selected in [Item] to Flash ROM
<OK> Writes the selected data to the BFM