7.5 Initializing the BFM and Flash ROM
7.5 Initializing the BFM and Flash ROM
Initializing [positioning parameters, servo parameters and table information] in the 20SSC-H BFM and Flash
ROM.
1 Select [Online] [Initialize module].
[Initialize module] dialog box appears.
2 Select the data to be initialized.
3 Click <OK>.
FX Configurator-FP initializes the selected data in the 20SSC-H BFM.
For the displayed messages, refer to Section 7.6.
Caution
While data on the X- or Y-axis cannot be initialized, data on both the X- and Y-axes stored in the unit cannot
be initialized.
Wait until data on both the X- and Y-axes can be initialized, and then initialize the unit.
Item Description
COM port Displays [COM port] in [Connection setup] dialog box
Transmission speed Displays [Transmission speed] in [Connection setup] dialog box
Module No. Displays [Module No.] in [Connection setup] dialog box
Item Ticks off the data to be initialized
Positioning parameters
Ticks off the axis of positioning parameters to be initialized
•X-axis
•Y-axis
Servo parameters
Ticks off the axis of servo parameters to be initialized
•X-axis
•Y-axis
Table information
Ticks off the axis of table information to be initialized
•X-axis
•Y-axis
•XY-axis
Flash ROM write Ticks off when initializing the Flash ROM data selected in [Item]
<OK> Initializes the selected data