6 Setting the connection destination
52
FX Configurator-FP
Operation Manual
Displayed messages
The message below appears depending on the communication setting.
Module Sets the module No. for 20SSC-H.
Module No.
Sets the module No. for 20SSC-H.
Setting range: 0 to 7
0
Time check
Sets the timeout determination time. Unit: second
Setting range: 1 to 9999 seconds
5 seconds
<Comm. Test> Executes the communication test.
Displayed Message Description
Cannot communicate with the PLC.
Execute again after checking the connections with the
PLC.
<ES: Error code>
A communication error has occurred. Check the
connection with PLC, and the communication settings at
the destination.
The connected PLC does not support this function.
Please execute again after confirming the version of the
PLC.
The connected PLC is not supported.
Confirm the version of the PLC.
The module which supported this function is not found.
Please execute again after confirming the module.
The special function block with assigned module No. is
not 20SSC-H.
Confirm the module No. and the connection between PLC
and 20SSC-H.
Don't change connection data while online.
User has selected [Connection setup] menu while
monitoring.
(displaying operation monitor or the table information edit
window for monitoring).
Select [Connection setup] menu after disrupting the
monitoring.
Module No. is range over.
User set the value outside the module No. range.
Confirm the module No.
Time check is range over.
User set the value outside the time check range.
Confirm the time check setting.
Item Description Default setting