8 Debug in the positioning
8.2 Testing the Operation
82
FX Configurator-FP
Operation Manual
*1. For the user unit, refer to the following.
Refer to Section 5.1.
3 Click <REQ. OPR>.
20SSC-H starts the OPR.
Item Description
Monitor item
Displays present address, Operation speed present value, status information and Error
code
Present address
Displays the present address [Unit : User unit
*1
]
Operation speed present
value
Displays the operation speed present value [Unit : User unit
*1
]
READY/BUSY
Displays status information
• READY: ON
•BUSY: OFF
Error code
Displays error codes
Displays 0 with no error
OPR type Displays the machine OPR as an OPR type
OPR mode
Displays the OPR mode
(Displays the OPR mode in the 20SSC-H positioning parameter)
•DOG
•Data set
• Stopper #1
• Stopper #2
OPR speed
Displays the OPR speed(High speed) stored in the positioning parameter
[Unit : User unit
*1
]
OP address
Displays the OP address stored in the positioning parameter
[Unit : User unit
*1
]
<REQ. OPR> Executes the mechanical OPR by the specified OPR type
<All axis stop> Stops all axis
<Stop> Stops the axis in operation test
<Close> Cancels the setting, and closes the dialog box