7210 SAS-M, T, R6, R12, Mxp, Sx, S Basic System
Configuration Guide
Virtual Chassis
Edition: 01 3HE 16132 AAAB TQZZA 235
-------------------------------------------------------------------------------
Net Ingress Qos resource : disable
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Sap Ingress ACL resource : 2
-------------------------------------------------------------------------------
IPv4 Resource : max Mac Resource : max
IPv4-IPv6 128 bit Resource : disable IPv6 64 bit Resource : disable
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Eth CFM : 2
-------------------------------------------------------------------------------
sap-down-mep : 1 up-mep : disable
sdp-down-mep-ing-mip : 1
-------------------------------------------------------------------------------
Egress Internal CAM : 2
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Sap Egress ACL resource : 2
-------------------------------------------------------------------------------
Mac and IPv4 Resource : 2 Mac-only Resource : disable
IPv6 128 bit Resource : disable Mac and IPv6 64 bit Resour*: disable
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
Egr sap agg-meter : disable
-------------------------------------------------------------------------------
MBS pool : Node
-------------------------------------------------------------------------------
Decommissioned Ports : Not Applicable
-------------------------------------------------------------------------------
===============================================================================
* indicates that the corresponding row element may have been truncated.
# indicates that the value will take effect only after reboot or clear card.
5.6 VC Boot Scenarios
This section describes the required configurations and the expected behaviors of
different boot up scenarios.
5.6.1 First Time Manual Boot of Nodes in the Stack
The following steps outline how to manually bring up a VC using nodes shipped from
the factory that are being booted up for the first time.