System Management
354
7210 SAS-M, T, R6, R12, Mxp, Sx, S Basic System
Configuration Guide
3HE 16132 AAAB TQZZA Edition: 01
6.11.5 System Timing
When synchronous Ethernet is enabled, the operator can select an Ethernet port as
a candidate for timing reference. The timing information recovered from this port is
used to time the system.
6.11.5.1 CLI command Syntax for 7210 SAS Platforms
This section describes the CLI command syntax to enable synchronous Ethernet on
specific 7210 SAS platforms.
6.11.5.1.1 CLI Syntax for the 7210 SAS-M
The following is a sample CLI configuration for the 7210 SAS-M.
*A:MTU>config>system>sync-if-timing# info detail
----------------------------------------------
no ql-selection
ref-order ref1 ref2
ref1
shutdown
no source-port
no ql-override
exit
ref2
shutdown
no source-port
no ql-override
exit
ptp
shutdown
no ql-override
exit
no revert
----------------------------------------------
*A:MTU>config>system>sync-if-timing#
6.11.5.1.2 CLI Syntax for 7210 SAS-R6 and 7210 SAS-R12
The following is a sample CLI configuration for the 7210 SAS-R6 and
7210 SAS-R12.
*A:sasr_dutb>config>system>sync-if-timing# info detail
----------------------------------------------
no ql-selection