Operating Parameters
B-2
Part 1024496_06
2014 Nordson Corporation
Standard
0 Enter Password
Description:
A user‐defined password that prevents unauthorized
changes to set‐point temperatures and operating
parameters.
Value:
0 to 9999
Resolution:
1
Default Value:
4000
Format:
—
Use:
This parameter only appears if a password is created
using parameter 11 and then enabled using parameter 10.
NOTE: The melter remains in the password‐protected
mode for two minutes after the last key press. After exiting
the setup mode, attempting to re‐enter the setup mode,
even before two minutes has elapsed, will require you to
re‐enter the password.
1
Total Hours with Heaters On (Noneditable)
Description:
A non editable value that indicates the total number of hours that the
heaters have been on.
Value:
999,999 (using abbreviated convention described below)
Resolution:
1 hour
Default Value:
0
Format:
—
Use:
The right display indicates up to 9999 hours of heater operation. When
the accumulated heater hours reaches 10,000, the display alternates
every two seconds between the three left most digits (thousands) and
the three right digits (hundreds). For example, 10,001 hours would be
displayed as ”10,” for two seconds and then ”001” for two seconds. The
comma is present if parameter 20, Temperature Units, is set to degrees
Fahrenheit. A period is present if parameter 20 is set to degrees
Celsius.
2
Fault Log (Noneditable)
Description:
Stores a record of the last ten faults.
Value:
—
Resolution:
—
Default Value:
_-F0 (unused log entry)
Format:
F1, F2, F3, and F4
Use:
Use the right-display scroll keys to review the log entries for the last ten
faults. Empty log entries are indicated by “_-F0.” Refer to Monitor the
Melter in Section 4, Operation.