Operation
4-21
Part 1024496_06
2014 Nordson Corporation
To adjust the set‐point temperature of an individual component
1. Press and hold the Tank, Hose, or Gun key for three seconds.
If the tank key was pressed, the left display indicates 1 (Flashing). If a
hose or gun key was pressed, the left display indicates the number of the
first sequential hose or gun (Flashing). The right display indicates the
current set‐point temperature of the component indicated in the left
display.
2. Scroll the left display to the number of the desired component.
The right display indicates the current set‐point temperature of the
component that you selected in the left display.
3. Press the Enter key.
The right display flashes.
4. Use the keypad to enter the set‐point temperature recommended by
the manufacturer of the hot melt. Refer to the technical data
sheet provided by the manufacturer of the hot melt to determine the
optimal set‐point temperature.
NOTE: If the keypad or the right‐display scroll keys have no affect on the
right display, the melter is password protected. You must enter a valid
password before you can change set‐point temperatures. Refer to
Entering the Melter Password later in this section.
5. Do one of the following:
To register the new set‐point temperature and then move on to
change the set‐point temperature of the next sequential component,
press the Enter key and then repeat steps 4 and 5.
To register the new set‐point temperature and return to the automatic
scan mode, go to step 6.
6. Press any component key (tank, hose, or gun).
The selected component begins to heat or cool to its new
set‐point temperature.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson ProBlue P10 and is the answer not in the manual?

Nordson ProBlue P10 Specifications

General IconGeneral
BrandNordson
ModelProBlue P10
CategoryMelting Machines
LanguageEnglish

Related product manuals