Operating Parameters
B-20
Part 1024496_06
2014 Nordson Corporation
Seven‐day Clock (contd)
68
Schedule 3 Exit Standby
Description:
Used to set the time that the melter will exit the standby mode during
schedule 3.
Value:
0000 to 2359, - - - -
Resolution:
1 minute
Default Value:
- - - -
Format:
Hour, Hour: Minute, Minute
Use:
Set the time that the melter will exit the standby mode during schedule
3.
To disable this parameter, set the parameter’s value to “- - - -” by
simultaneously pressing both of the right-display scroll keys.
Note: Do not set an exit standby time that is outside of the time period
defined by the schedule’s heater on and off time. The melter cannot
enter the standby mode when the heaters are off.
71
Schedules for Monday
Description:
Used to select which schedule(s) should be used on Monday.
Value:
0 – Remain at last clock transition
1 – Use just schedule 1
2 – Use just schedule 2
3 – Use just schedule 3
4 – Use schedule 1 and 2
5 – Use schedule 2 and 3
6 – Use schedule 1 and 3
7 – Use schedule 1, 2, and 3
Resolution:
1
Default Value:
0
Format:
Use:
Selects the active schedule(s) for the day.
NOTES: If the 0 schedule option is used, the heaters will not turn on
again until the next scheduled heaters on time arrives.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson ProBlue P10 and is the answer not in the manual?

Nordson ProBlue P10 Specifications

General IconGeneral
BrandNordson
ModelProBlue P10
CategoryMelting Machines
LanguageEnglish

Related product manuals