Operating Parameters
B-9
Part 1024496_06
2014 Nordson Corporation
Input Setup
30
Standard Input 1
Description:
Control options that determine the function of input 1.
Value:
0 – Input Disabled
1 – Standby On/Off
2 – Heaters On/Off
3 – Pump Enable/Disable
4 – Hose/Gun 1 Enable/Disable
5 – Hose/Gun 2 Enable/Disable
6 – Hose/Gun 3 Enable/Disable
7 – Hose/Gun 4 Enable/Disable
8 – Hose/Gun 5 Enable/Disable
9 – Hose/Gun 6 Enable/Disable
10 – Automatic standby
11 – Motor 2 Enable/Disable (DuraBlue adhesive melters only)
Resolution:
1
Default Value:
10
Format:
—
Use:
Multiple inputs can be set to the same input value. After one or more
inputs that have the same input value are energized, the input
functionality will not be considered inactive (off) until all of the inputs
with the same input value are de-energized (Multiple inputs set to the
same input value are logical ORed.).
31
Standard Input 2
Description:
Control options that determine the function of input 2.
Value:
0 – Input Disabled
1 – Standby On/Off
2 – Heaters On/Off
3 – Pump Enable/Disable
4 – Hose/Gun 1 Enable/Disable
5 – Hose/Gun 2 Enable/Disable
6 – Hose/Gun 3 Enable/Disable
7 – Hose/Gun 4 Enable/Disable
8 – Hose/Gun 5 Enable/Disable
9 – Hose/Gun 6 Enable/Disable
11 – Motor 2 Enable/Disable (DuraBlue adhesive melters only)
Resolution:
1
Default Value:
1
Format:
—
Use:
Multiple inputs can be set to the same input value. After one or more
inputs that have the same input value are energized, the input
functionality will not be considered inactive (off) until all of the inputs
with the same input value are de-energized (Multiple inputs set to the
same input value are logical ORed.).