Rockwell Automation Publication 2080-UM002L-EN-E - November 2021 69
Chapter 5 Communication Connections
5. Set Port State as Enabled or Disabled.
6.
To manually set connection speed and duplexity, uncheck the option
box
Auto-Negotiate speed and duplexity. Then, set Speed (10 Mbps or 100
Mbps) and Duplexity (Half o
r Full) values.
7. Click Save Settings to Controller if you would like to save the settings
to
your controller.
8.
On the device configuration tree, under Ethernet, click Port Diagnostics
to monitor Interface and Media counters. The counters are available an
d
updated when the controller is in Debug mode.
Validate IP Address
Modules must validate the incoming IP address configuration, whether it is
obtained through explicit configuration or through DHCP.
The following rules must be obeyed when configuring the IP address:
• The IP address for the module cannot be set to zero, a multicast addr
ess,
a bro
adcast address, or an address on the Class A loopba
ck network
(127.
x.x.x).
• The IP address should not start with zero, and the IP address network ID
should be not zero.
• The Network mask cannot be set to 255.255.255.255.
• The Gateway address must be on the same subnet as the IP addr
ess that
is
being configured.
• The Name Server address cannot be set to zero, a multicast ad
dress, a
broa
dcast address, or an address on the Class A loopback netw
ork
(127.
x.x.x).
The valid range of static IPv4 IP address exclude:
• Broadcast or zero IP (255.255.255.255 or 0.0.0.0)
• IP address starting with 0 or 127 (0.xxx.xxx.xxx or 127.xxx.xxx.xxx)
• IP address ending with 0 or 255 (xxx.xxx.xxx.0 or xxx.xxx.xxx.255)
• IP addresses in range 169.254.xxx.xxx (169.254.0.0 to 169.254.255.255)
• IP addresses in range 224.0.0.0 to 255.255.255.255
Ethernet Host Name
Micro800 controllers implement unique host names for each controller, to be
used to identify the controller on the network. The default host name is
comprised of two parts: product type and MAC address, separated by a
hyphen. For example: 2080LC50-xxxxxxxxxxxx, where xxxxxxxxxxxx is the
MAC address.
The user can change the host name using the CIP Service Set Attribute Single
when the controller is in Program/Remote Program mode.

Table of Contents

Other manuals for Rockwell Automation Allen-Bradley Micro830

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation Allen-Bradley Micro830 and is the answer not in the manual?

Rockwell Automation Allen-Bradley Micro830 Specifications

General IconGeneral
BrandRockwell Automation
ModelAllen-Bradley Micro830
CategoryController
LanguageEnglish

Related product manuals