If the coin is not rejected when the REJECT button is pressed, open the coin chute door and open the selector gate.
After removing the jammed coin, put a normal coin in and check to see that the selector correctly functions.
The Coin Selector should be cleaned once every 3 months.
When cleaning, follow the procedure below:
12-1 FIG 1
● Remove and clean smears by using a soft cloth dipped in water or diluted
chemical detergent and then squeezed dry.
● Never apply machine oil, etc. to the Coin Selector.
● After cleaning the Coin Selector, insert a regular coin in the normal
working status and ensure that the selector correctly functions.
12-1 CLEANING THE COIN SELECTOR
GATE
Handling the Coin Jam
12 COIN HANDLING
1
2
3
Turn the power for the machine OFF. Open the Coin Chute Door
Remove the Coin Selector from the Coin Chute Door
Open the gate and dust off by using a soft brush (Small soft Paint Brush, etc.)