15-4
OP27,
OP37 Equipment Manual
Release 05/99
15.2 Changing Between OP and DOS Modes
Proceed
as follows to switch from OP mode to DOS mode:
Step Action
1 Press the three arrow keys depicted on the right
simultaneously while the OP is starting up.
++
2 The OP then requests the boot medium. Select:
Disk for hard disk/floppy disk drive
PCMCIA: HD
for memory module.
3 The OP then boots from the medium specified and starts up again, this
time in DOS mode. This presupposes that the medium has been formatted
as a boot medium.
The DOS mode setting remains stored for future startups of the OP37.
Switching
from DOS mode to OP mode is performed using the BIOS Setup, as
described in Chapter 15.1.
Change
from OP
mode to DOS
mode
Changing from
DOS mode to OP
mode
Operating modes