Page #63 background image
I
NITIAL
C
ONFIGURATION
2-15
5. To set the IP address of the IPv6 default gateway for the network to
which the switch belongs, type “ipv6 default-gateway gateway,” where
“gateway” is the IPv6 address of the default gateway. Press <Enter>.
Dynamic Configuration
Obtaining an IPv4 Address
If you select the “bootp” or “dhcp” option, IP will be enabled but will not
function until a BOOTP or DHCP reply has been received. You therefore
need to use the “ip dhcp restart client” command to start broadcasting
service requests. Requests will be sent periodically in an effort to obtain IP
configuration information. (BOOTP and DHCP values can include the IP
address, subnet mask, and default gateway.)
If the “bootp” or “dhcp” option is saved to the startup-config file (step 6),
then the switch will start broadcasting service requests as soon as it is
powered on.
Console(config)#ipv6 general-prefix rd 2001:DB8:2222::/4836-12
Console(config)#interface vlan 1 24-2
Console(config-if)#ipv6 address rd 0:0:0:7272::72/64 36-14
Console(config-if)#exit
Console(config)ipv6 default-gateway
2001:DB8:2222:7272::254 36-24
Console(config)end
Console#show ipv6 interface 36-22
Vlan 1 is up
IPv6 is enable.
Link-local address:
FE80::200:E8FF:FE90:0/64
Global unicast address(es):
2001:DB8:2222:7272::72, subnet is 2001:DB8:2222:7272::/64
Joined group address(es):
FF01::1/16
FF02::1/16
FF02::1:FF72:64/104
FF02::1:FF90:0/104
MTU is 1500 bytes.
ND DAD is enabled, number of DAD attempts: 1.
ND retransmit interval is 1000 milliseconds
Console#show ipv6 default-gateway 36-25
ipv6 default gateway: 2001:DB8:2222:7272::254

Table of Contents

Other manuals for SMC Networks TigerStack II SMC8848M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks TigerStack II SMC8848M and is the answer not in the manual?

SMC Networks TigerStack II SMC8848M Specifications

General IconGeneral
BrandSMC Networks
ModelTigerStack II SMC8848M
CategorySwitch
LanguageEnglish

Related product manuals