156 bright blue Installation Manual
4 Put the PIM400 into Pairing Mode (this is necessary for the PDA to be able to make changes to the PIM's
settings).
a) On the PIM400, hold down the Link 1 (S2) button.
b) Press the Link 2 (S3) button three times while continuing to hold down the Link 1 button. The red LEDs
in the Schlage button will flash. The lock is now in pairing mode.
5 On the PDA click the Pair PDA to Device option. A pop-up will display when the pairing process is
complete.
Note: You only need to pair the PIM400 to the PDA once. After pairing the PIM400 and PDA will
communicate whenever connected.
Set PIM400 Address
The SUS is used to set the address of the PIM400. The address of the PIM should be set to the lowest number
available, from 0 to 15. A maximum of sixteen (16) AD-400 Locks can communicate with a PIM400 module on the
same channel, with all reader types. The address used by the PIM400 and AD-400 locks go from 0 to 15 in the
SUS and in the bright blue interface. However, the rest of the locks in bright blue use an address list of 1
through 16. When addressing a PIM400 or AD-400 lock, it is important to remember this. An address of 0 for the
PIM400 or AD-400 lock, in SUS, equals an address of 1 for the rest of the locks in bright blue. The PIM400 will
have the same address as the AD-400 lock with the lowest address.
When setting the address of the PIM400 you must also designate the range of addresses being used by the AD-
400 locks that will communicate with this PIM400, designating both a low and a high address for the doors. This
allows the system to know which addresses to keep open for the AD-400 locks.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt bright blue and is the answer not in the manual?

Vanderbilt bright blue Specifications

General IconGeneral
BrandVanderbilt
Modelbright blue
CategorySecurity Sensors
LanguageEnglish

Related product manuals