Chapter 13 Schlage NDE Series
Wireless Locks with ENGAGE 171
Operational environment
Temperature: -35°C to +66°C
Humidity: 0% to 100% non-condensing
Card Reader - Proximity Reader
125 kHz and 12.56 MHz smart credentials
ISO standard 15693 and ISO 14443
Card Read Range: up to 1.25” on 125 kHz proximity credentials
up to 0.75” on 13.56 MHz smart credentials
125 kHz proximity credentials compatibility:
Schlage, XceedID, HID, GE/CASE PRoxLite, AWID and LenelProx
13.56 MHz smart credential compatibility:
Secure Sector: Schlage MIFARE, aptiQ MIFARE Classic, XceedID,
aptiQ MIFARE DESFire EV1 with PACSA, aptiQ mobile
CDN Only: DESFire, HID iClasss, Inside Contactless Pico Tag,
MIFARE, MIFARE DESFire EV1, ST Microelectronics,
Texas Instruments Tag-It, Phillips I-Code
Wiegand output
Certifications: UL 294, UL10C, FCC Part 15, ADA, RoHS, Industry Canada (IC)
ESD Protection: 12KV
Card formats: Above specified card formats up to 255-bit
Request-to-exit: built-in switch will be triggered from the activation of the door lever on the protected side of the
door.
Clutch position: Schlage NDE locks provide a way to lock or unlock a door and monitor access from a remote
location. Schlage NDE locks are fail-safe from the protected side of the door. These locksets are controlled by the
bright blue system.
Door position: built-in magnetic Door Position Switch (DPS) used to report Door Open, Door Forced or Door
Held events. Must be calibrated via ENGAGE mobile app during lock commissioning. Will report out of calibration.
GWE ENGAGE Gateway Wiring Instructions
Power
bright blue 12 24 VDC
GWE ENGAGE Gateway powered by bright blue or external 24 VDC power supply
bright blue to GWE ENGAGE Gateway
Controller to Gateway via RS-485 wiring max 4000’
Device 1 1
GWE ENGAGE Gateway
RXD (A)
TX
TXD (B)
TX+

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt bright blue and is the answer not in the manual?

Vanderbilt bright blue Specifications

General IconGeneral
BrandVanderbilt
Modelbright blue
CategorySecurity Sensors
LanguageEnglish

Related product manuals