114
Error
counter
Position
loop gain
Kp
Speed
control Kv,
Ti
Torque
instruction
filter Tf
Current
control
M
PG
Servo motor
encoder
Current loop
Speed loop
Speed
instruction
Position
loop
+
-
+
-
+
-
Pulse instruction
Upper device
Servo unit
Position
control loop
Speed
control loop
Model
loop
Torque
feedforward
Speed
feedforward
Position control loop diagram (turn on the model loop)
Servo unit consists of three feedback loops (current loop, speed loop and position loop) from inside to
outside. The more inner loop, the more responsive it is. Failure to comply with this principle will result
in poor response or vibration. Among them, the current loop parameters are fixed values to ensure
adequate responsiveness, and users do not need to adjust.
Please use manual adjustment in the following occasions:
When the expected effect can not be achieved by fast adjusting the gain
When the expected effect is not achieved by automatically adjusting the gain
6.6.2 Adjustment steps
In position mode, if the soft mode (P2-02.0=1) is selected by auto-tuning, the function of model loop
will be turned off; in speed mode, the gain of position loop will be invalid.
Increasing response time
1. Reducing the filter time constant of torque instruction (P2-35)
2. Increasing Speed Loop Gain (P1-00)
3. Reducing Integral Time Parameter of Speed Loop (P1-01)
4. Increasing the gain of position loop (P1-02)
5. Improving Model Loop Gain (P2-49)
Reduce response, prevent vibration and overshoot
1. Reducing the Speed Loop Gain (P1-00)
2. Increasing Integral Time Constant of Speed Loop (P1-01)
3. Reducing the gain of position loop (P1-02)
4. Increase the filter time constant of the torque instruction (P2-35)
5. Reducing Model Loop Gain (P2-49)
6.6.3 Gain parameters for adjustment
The gain parameters that need to be adjusted:
P1-00 Speed Loop Gain
P1-01 Integral Time Constant of Speed Loop
P1-02 position loop gain
P2-35 Torque Instruction Filtering Time Constant

Table of Contents

Other manuals for Xinje DS5E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS5E Series and is the answer not in the manual?

Xinje DS5E Series Specifications

General IconGeneral
BrandXinje
ModelDS5E Series
CategoryServo Drives
LanguageEnglish

Related product manuals