40
Reverse mode
CW is forward
rotation
Parameter
Setting
Meaning
P0-05
0 (default)
Standard setting (CCW is forward rotation)
1
Reverse mode (CW is forward rotation)
5.2.3 Stop mode
The stop mode when servo is off or alarm.
Parameter
Meaning
Default
setting
Unit
Range
Change
Effective
P0-27
Servo OFF stop
mode
0
-
0 or 2
Servo
OFF
At once
P0-29
Alarming stop
mode
2
-
0 or 2
Servo
OFF
At once
0: Inertial operation stops and remains in inertial operation after stopping.
2: The deceleration brake stops, and the inertia running state is maintained after the stop.
Parameter
Meaning
Default
setting
Unit
Range
Change
Effective
P0-30
Stop overtime time
20000
1ms
065535
Servo
OFF
At once
P3-32
Break torque
300
1%
01000
Anytime
At once
Note:
(1) When the stop mode is set to 0, the motor starts to stop by inertia when the servo OFF occurs and
the alarm occurs, and then turns to free stop when the speed is less than P5-03 (rotation detection
speed). The servo will time the inertial stop process. In the process of inertial stopping, if the timing
time is longer than P0-30 and the motor speed has not been reduced below P5-03, the servo will stop
freely and give the stop timeout alarming.
(2) When the stopping mode is set to 2, the motor will produce a braking torque of P3-32 after the
occurrence of servo OFF and alarm. The motor will start braking and stop until the speed is less than
P5-03 (rotation detection speed), and then turn to free stop. At the same time, the servo will timing the
braking stop stage. In the process of inertial stopping, if the timing time is longer than P0-30 and the
motor speed has not been reduced below P5-03, the servo will stop freely and give the stop timeout
alarming.
Set the stop mode when overrun.
Parameter
Meaning
Default
setting
Unit
Range
Change
Effective
P0-28
Servo overrun stop
mode
2
-
03
Servo
OFF
At once
Parameter
Value
Meaning
P0-28
0
The deceleration stops 1, the overrun direction moment is 0 after
stopping, and receiving instructions.
1
Inertia stops, after stopping, overrun direction moment is 0,
receiving instructions.
2
The deceleration stops 2, after stopping, the overrun direction does
CW
CCW

Table of Contents

Other manuals for Xinje DS5E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS5E Series and is the answer not in the manual?

Xinje DS5E Series Specifications

General IconGeneral
BrandXinje
ModelDS5E Series
CategoryServo Drives
LanguageEnglish

Related product manuals