50
5.3.4 Position command filter
Parameter
Meaning
Default
setting
Unit
Range
Change
Effective
P1-24
First-order
low-pass filtering
time of position
instruction
0
0.1ms
065535
Servo
OFF
At once
P1-25
Position instruction
smoothing filtering
time
0
0.1ms
065535
Servo
OFF
At once
When set to 0, the filter becomes invalid.
First-order low-pass filter of position
instruction
Position instruction smoothing filter
P1-24
P1-24
63.2%
100%
36.8%
Command pulse
frequency
T
Before filtering
After filtering
P1-25
P1-25
100%
Command pulse
frequency
T
Before filtering
After filtering
P1-25
P1-25
100%
Command pulse
frequency
T
Before filtering
After filtering
5.3.5 Pulse offset clear/CLR
Pulse deviation value refers to the difference between the command pulse of the command controller
(such as PLC) and the feedback pulse of the servo unit in the position mode. Its unit is 1 command unit,
which is related to the command unit determined by the electronic gear ratio.
Parameter
Signal
name
Setting
Meaning
Range
P5-34
Pulse
offset clear
/CLR
n.0000
(default)
Default unallocated input terminal
The range of parameters
is 0001-0014.
can be assigned to other
input terminals through
P5-34.
n.0002
Use SI2 input signal

Table of Contents

Other manuals for Xinje DS5E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS5E Series and is the answer not in the manual?

Xinje DS5E Series Specifications

General IconGeneral
BrandXinje
ModelDS5E Series
CategoryServo Drives
LanguageEnglish

Related product manuals