123
and the speed is lower than P0-75
(unit 1 rpm).
20
0
E-200
Regenerative resistance overload
22
0
E-220
Communication error of absolute
servo encoder
Servo OFF
2
E-222
Absolute value servo encoder
battery low voltage alarm (can
shield this alarm)
Servo OFF
3
E-223
Absolute value servo encoder data
access alarm
Servo OFF
8
E-228
Absolute Servo Encoder Value
Overflow
Servo OFF
26
0
E-260
Over range alarm
1
E-261
Overrun signal connection error
2
E-262
Control stop timeout
Servo OFF
4
E-264
Excessive vibration
28
0
E-280
read motor code inside encoder
error
Servo OFF
31
0
E-310
motor code error
Servo OFF
1
E-311
motor code lost
Servo OFF
4
E-314
The motor code does not match
the software version
Servo OFF
7.2 Analysis of alarm types
DS5 alarm code format is E-XX□, “XX” means main type, “□” means sub-type.
Type
Code
Description
Reasons
Solutions
EE
EE
1
EEEE1
Communication
error between
panel and CPU
(1) Voltage
fluctuation of power
supply is large, and
low voltage leads to
failure of panel
refresh; (2) Damage of
panel program
(1) Stable power supply to
ensure the stability of power
supply voltage.
(2) after repower on the driver, if
the alarm cannot be removed,
please contact the agent or the
manufacturer.
2
EEEE2
3
EEEE3
4
EEEE4
01
0
E-010
Firmware version
mismatch
Downloaded firmware
version error
please contact the agent or the
manufacturer
2
E-012
System Loading
Error
Program damage
please contact the agent or the
manufacturer
3
E-013
FPGA Loading
Error
(1) Program damage
(2) Device damage
please contact the agent or the
manufacturer
4
E-014
FPGA Access
error
(1) Program damage
(2) Device damage
(3) serious external
interference
please contact the agent or the
manufacturer
5
E-015
Program running
error
Program damage
please contact the agent or the
manufacturer
6
E-016
Processor Running
Error
Hardware damage
please contact the agent or the
manufacturer
7
E-017
Processor Running
Timeout
Program damage
please contact the agent or the
manufacturer
8
E-018
FPGA running
timeout
Program damage
please contact the agent or the
manufacturer
9
E-019
System password
error
Program damage
please contact the agent or the
manufacturer
02
0
E-020
Parameter loading
Failure of parameter
Re-energizing can restore default

Table of Contents

Other manuals for Xinje DS5E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS5E Series and is the answer not in the manual?

Xinje DS5E Series Specifications

General IconGeneral
BrandXinje
ModelDS5E Series
CategoryServo Drives
LanguageEnglish

Related product manuals