123
and the speed is lower than P0-75
(unit 1 rpm).
Regenerative resistance overload
Communication error of absolute
servo encoder
Absolute value servo encoder
battery low voltage alarm (can
shield this alarm)
Absolute value servo encoder data
access alarm
Absolute Servo Encoder Value
Overflow
Overrun signal connection error
read motor code inside encoder
error
The motor code does not match
the software version
7.2 Analysis of alarm types
DS5 alarm code format is E-XX□, “XX” means main type, “□” means sub-type.
Communication
error between
panel and CPU
(1) Voltage
fluctuation of power
supply is large, and
low voltage leads to
failure of panel
refresh; (2) Damage of
panel program
(1) Stable power supply to
ensure the stability of power
supply voltage.
(2) after repower on the driver, if
the alarm cannot be removed,
please contact the agent or the
manufacturer.
Firmware version
mismatch
Downloaded firmware
version error
please contact the agent or the
manufacturer
please contact the agent or the
manufacturer
please contact the agent or the
manufacturer
(2) Device damage
(3) serious external
interference
please contact the agent or the
manufacturer
please contact the agent or the
manufacturer
please contact the agent or the
manufacturer
Processor Running
Timeout
please contact the agent or the
manufacturer
please contact the agent or the
manufacturer
please contact the agent or the
manufacturer
Re-energizing can restore default