5.12.4 Servo ready output/S-RDY
Parameter
Signal
name
Setting
Meaning
修改范围
P5-41
Ready
/S-RDY
n.0003
(default)
SO3 and COM pass through when
servo is ready
The range is 0000-0013. It
can distribute to other
output terminal through
P5-41.
n.0013
SO3 and COM cut off when servo
is ready
Note:
(1) S-RDY output condition selection, set by P5-70:
(2) When P5-70 is set to 0, the terminal is turned on after the initialization of the driver is
completed and the servo has no alarm state.
(3) P5-70 is set to 1: This terminal will not be turned on until it is enabled and the servo has no
alarm status.
5.12.5 Encoder Z phase output/Z
parameter
Meaning
Default
setting
Unit
Range
Modify
Effective
P5-48
Z phase output /Z
n.0000
-
00000014
Anytime
At once
P5-19
Z phase pulse
width
2
ms
220
Anytime
At once
1. /Z signal can be distributed to the output terminal through P5-48.
2. Z phase signal is single pulse output mode, the default pusle width is 2ms, it can set through P5-19,
it is not related to the motor speed.
Encoder Z phase signal
P5-48=n.0011
SO1 output
P5-48=n.0001
SO1 output
2ms

Table of Contents

Other manuals for Xinje DS5E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS5E Series and is the answer not in the manual?

Xinje DS5E Series Specifications

General IconGeneral
BrandXinje
ModelDS5E Series
CategoryServo Drives
LanguageEnglish

Related product manuals