EasyManuals Logo
Home>Xinje>Servo Drives>DS5E Series

Xinje DS5E Series User Manual

Xinje DS5E Series
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #60 background imageLoading...
Page #60 background image
52
1
After the
instruction is
finished, the
deviation is below
P5-00 and COIN
signal is output.
U0-08
Pulse offset
P5-00
ON
/S-ON
Signal status
/COIN
Signal status
ONON
OFF
ΔU0-12
Pulse command
2
When the
instruction ends
and the motor
speed is under the
rotation detection
speed (P5-03) and
the absolute
deviation is less
than P5-00, the
COIN signal is
output.
U0-08
Pulse offset
P5-00
ON
/S-ON
Signal status
/COIN
Signal status
ONON
OFF
ΔU0-12
Pulse command
U0-00
Actual speed
P5-03
3
At the end of
instruction, the
absolute deviation
value under P5-00,
it outputs COIN
signal. If COIN
maintains P5-02
time, COIN-HOLD
signal is output.
U0-08
Pulse offset
P5-00
ON
/S-ON
Signal status
/COIN
Signal status
ONON
OFF
ΔU0-12
Pulse command
/COIN-HOLD
Signal status
ON
OFF
P5-02
P5-02
5.3.7 Positioning near signal/NEAR
Parameter
Signal name
Setting
Meaning
Range
P5-46
Positioning
near /NEAR
n.0000
(default)
Default unallocated output
terminal
The range of parameters
is 0001-0014.
can be assigned to other
output terminals through
P5-46.
n.0002
Output signal from SO2 terminal

Table of Contents

Other manuals for Xinje DS5E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS5E Series and is the answer not in the manual?

Xinje DS5E Series Specifications

General IconGeneral
BrandXinje
ModelDS5E Series
CategoryServo Drives
LanguageEnglish

Related product manuals