46
direction determines the rotation direction of the motor. Therefore, this parameter can be adjusted if
the actual rotation direction of the motor is different from the expected direction in the position mode.
2. set the pulse instruction form
Parameter
Meaning
setting
Meaning
Change
Effective
P0-10
n.xxx0
Pulse
instruction
form
0
CW, CCW mode
Servo
OFF
At once
1
AB phase
2
Pulse+direction(default)
3. Details of pulse instruction
P0-10xxx□
Forward rotation
Reverse rotation
0
CW/CCW
CCW
CW
OFF
CCW
CW
OFF
1AB
90°
Phase A
Phase B
90°
Phase A
Phase B
2P+D
pulse
direction
ON
pulse
direction
OFF
5.3.3 Electronic gear ratio
Parameter
Meaning
Default
setting
Unit
Range
Change
Effective
P0-11
Pulse numbers per
rotation *1
0
pul
09999
Servo OFF
At once
P0-12
Pulse numbers per
rotation *10000
1
pul
09999
Servo OFF
At once
P0-13
Electronic gear
ratio (numerator)
1
-
065535
Servo OFF
At once
P0-14
Electronic gear
ratio (denominator)
1
-
065535
Servo OFF
At once
P0-92
Group 2 Electronic
gear ratio
(numerator) low
bit*1
1
-
19999
Servo OFF
At once
P0-93
Group 2 Electronic
gear ratio
0
-
165535
Servo OFF
At once

Table of Contents

Other manuals for Xinje DS5E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS5E Series and is the answer not in the manual?

Xinje DS5E Series Specifications

General IconGeneral
BrandXinje
ModelDS5E Series
CategoryServo Drives
LanguageEnglish

Related product manuals