63
5.6.1 Control mode selection
Parameter
Set
value
Meaning
Modify
Effective
P0-01
3
Speed control: internal speed selection
Servo
OFF
Immediat
ely
Function: internal speed selection will set 3 motor speeds and select the speed by external signal. It is
no need to configure external speed generator or pulse generator.
5.6.2 Internal speed setting
Parameter
Meaning
Defaulted
setting
Unit
Range
Modify
Effective
P3-05
Internal speed 1
0
rpm
-9999+9999
Anytime
At once
P3-06
Internal speed 2
0
rpm
-9999+9999
Anytime
At once
P3-07
Internal speed 3
0
rpm
-9999+9999
Anytime
At once
5.6.3 Soft start
Parameter
Meaning
Defaulted
setting
Unit
Range
Modify
Effective
P3-09
Soft Start
Acceleration Time
0
ms
065535
Servo
OFF
At once
P3-10
Soft Start
deceleration Time
0
ms
065535
Servo
OFF
At once
Soft start acceleration and deceleration time is suitable for mode 3/4/7. Smooth speed control can be
carried out when step speed instruction is input or internal setting speed is selected.
P3-09: Time from stop to rated speed
P3-10: Time from rated speed to stop
M
Servo motor
Run the motor
at set speed
Servo unit
Speed selection
SPEED1 P3-05
SPEED2 P3-06
SPEED3 P3-07
User parameter
/SPD-D
/SPD-A
/SPD-B
Input
No need external speed or
pulse generator

Table of Contents

Other manuals for Xinje DS5E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS5E Series and is the answer not in the manual?

Xinje DS5E Series Specifications

General IconGeneral
BrandXinje
ModelDS5E Series
CategoryServo Drives
LanguageEnglish

Related product manuals