63
5.6.1 Control mode selection
Speed control: internal speed selection
Function: internal speed selection will set 3 motor speeds and select the speed by external signal. It is
no need to configure external speed generator or pulse generator.
5.6.2 Internal speed setting
5.6.3 Soft start
Soft Start
Acceleration Time
Soft Start
deceleration Time
Soft start acceleration and deceleration time is suitable for mode 3/4/7. Smooth speed control can be
carried out when step speed instruction is input or internal setting speed is selected.
P3-09: Time from stop to rated speed
P3-10: Time from rated speed to stop
Run the motor
at set speed
No need external speed or
pulse generator