Basic Programming 5 - 14
Table 5.3 Preset V/F Patterns
Specifications E1-03 V/F Pattern Specifications E1-03 V/F Pattern
General-purpose
50Hz 0
High Starting Torque
50Hz
High
Starting
Torque 1
8
High
Starting
Torque 2
9
60Hz
1
or
F
60Hz
High
Starting
Torque 1
A
60Hz
(with 50Hz Base)
2
High
Starting
Torque 2
B
72Hz
(with 60 Hz Base)
3
High Speed Operation
90Hz
(with 60Hz Base)
C
Variable Torque
50Hz
Variable
Torque 1
4
120Hz
(with 60Hz Base)
D
Variable
Torque 2
5
60Hz
Variable
Torque 1
6
180Hz
(with 60Hz Base)
E
Variable
Torque 2
7
IMPORTANT
When a factory initialization is performed and the setting of E1-03 = F or FF, E1-03 is unaffected, but the
settings of E1-04 through E1-13 are returned to their factory default settings.
(Hz)
(V)
230
17
10
01.32.5 50
0
230
(V)
28
22
15
13
(Hz)
01.32.5 50
9
8
(Hz)
01.53.0 50 60
17
10
2
1
F
(V)
230
230
(V)
28
22
17
13
(Hz)
01.53.0
B
A
60
(Hz)
01.53.0 60 72
17
10
3
(V)
230
(Hz)
01.53.0 60 90
17
10
C
(V)
230
230
(V)
57
40
10
9
(Hz)
0 1.3 25 50
5
4
(Hz)
0 1.5 3.0 60 120
17
10
D
(V)
230
230
(V)
57
40
10
9
(Hz)
01.5 30 60
7
6
(Hz)
0 1.5 3.0 60 180
17
10
E
(V)
230
Email: Sales@aotewell.com