171
MAINTENANCE INSTRUCTIONS
E715 E716 E717
INSTRUCTIONS FOR MAINTENANCE
OF DRY AIR FILTER WOODGATE
Maintain the air cleaner in the following
way:
1. Remove the bonnet side shield.
2. Screw off the wing nut of the air
cleaner cover.
REGENERATION OF THE MAIN AIR
FILTER ELEMENT WOODGATE
− Remove the main dry air filter element
In case that the main filter element has
not been damaged (no dust inside the air
filter element), regenerate it by means of
pressure air blowing through the element
from inside. The main air filter element
can be regenerated maximally three
times in such way. The main air filter
element needs to be replaced once in a
year.
REPLACEMENT OF SAFETY FILTER
ELEMENT WOODGATE
1. Screw off the wing nut securing the
safety element of the air cleaner.
2. Remove the safety element of the air
cleaner.
The safety filter element cannot
be recovered. It must be always
replaced in the following cases:
- if the main air filter element is
damaged
- after each 5th maintenance of
the air cleaner
- minimum once per two years