53
TRACTOR OPERATION
E204 E205 E206
IF THE ENGINE DOES NOT START
Turn the key into position "0", wait 30
seconds and repeat the start.
Maximum 6 starting cycles are allowed
(15 seconds starting and 30 second
interruption make one cycle). Further
engine starting attempt is allowed after
cooling down of starter motor to the
ambient temperature.
Never help the stopping engine
by the starter motor. It may be
suffer damage this way.
SIGNALLING OF GLOWING SYSTEM
FAILURES
Flashing of the glowing indicator light
indicates failure in the glowing system.
- If the glowing indicator light is flashing
once in a second with the stopped en-
gine, glowing will take place in emer-
gency regime as at low temperature
regardless to coolant temperature.
- If the glowing indicator light is flashing
twice in a second with the stopped en-
gine, the glowing is put of operation.
- If the glowing indicator light is flashing
permanently with the engine running,
failure of the glowing regulator oc-
curred and glowing was not finished. It
is necessary to correct the failure im-
mediately, because there is danger of
battery discharging.
STARTER MOTOR HANDLING
It is forbidden to start the trac-
tor by short circuit of starter
motor connectors!
Start the tractor from the
driver’s seat only!
When handling or repairing the
starter motor, remember to dis-
connect the negative battery
terminal and move all gearshift
levers into neutral position, in-
cluding PTO shaft engagement!
Starter motor connectors are
covered with caps.