MECHANICAL INSTALLATION
PRODUCT
ACS6000
DOCUMENT KIND
User manual
DOCUMENT ID.
3BHS212794 E01
REV.
N
LANG.
en
PAGE
113/266
5.10. Attaching the sealing tapes
This section applies to transport units with degree of protection IP 54.
The self-adhesive sealing tape (3BHB012376R0001) supplied with the drive (1 m per
transport unit) prevents water entering the gap between two adjoining roof plates.
The tape is installed where two transport units have been joined. Gaps within a
transport unit have been sealed with a tape in the factory.
Procedure
1. Remove the roof plates of two adjoining transport units.
2. Cut the sealing tape to the required length.
3. Attach the tape on the whole length of the joining crossbars (1).
Figure 5-21 Attach sealing tape to the joining crossbar (1)
4. Reinstall the roof plates.
1