3.3.5.1. DCS800 control panel
The control panel of the DCS800 unit enables the user to control, read the status
messages and set the parameters of the DCS800 unit. The panel can also be used
to copy parameters from one DCS800 unit to another DCS800.
For more information, see 8.5 EXU control panel on page 166.
3.3.5.2. Reversing switch
The EXU for brushless excitation is equipped with a reversing switch for changing
the sense of rotation. The switch is actuated by the drive.
The switch changes the sense of rotation via the optical communication link. When
the drive is in state ReadyOn or NotReadyOn, the switch is opened.
3.3.5.3. Output disconnector
The optional output disconnector is used to disconnect the EXU from the motor for
maintenance purposes.