EasyManuals Logo
Home>Cisco>Network Router>ASR 1001-X

Cisco ASR 1001-X User Manual

Cisco ASR 1001-X
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #71 background imageLoading...
Page #71 background image
Apr 21 03:42:45.619 EDT: %SYS-5-RELOAD: Reload requested by console. Reload Reason: Reload Command.Apr
21 03:42:59.920 R0/0: %PMAN-5-EXITACTION: Process manager is exiting: process exit with reload
chassis code
Step 4
After confirming the reload command, wait until the system bootstrap message is displayed before powering off the
system:
Example:
System Bootstrap, Version 15.4(2r)S, RELEASE SOFTWARE (fc1)
Copyright (c) 1994-2014 by cisco Systems, Inc.
Current image running: Boot ROM0
Last reset cause: LocalSoft
ASR1001-X platform with 16777216 Kbytes of main memory
rommon 1 >
Step 5
Place the Standby switch in the Standby position.
The fans in the power supply modules will continue to run even if the Standby switch is in the Standby position.Note
After powering off the router, wait for a minimum of 30 seconds before powering it on again.Note
Environmental Monitoring and Reporting Functions
Environmental monitoring and reporting functions allow you to maintain normal system operation by identifying
and resolving adverse conditions prior to loss of operation.
To prevent overheating of the chassis, ensure that your system is drawing cool inlet air. Over temperature
conditions may occur if the system is drawing in the exhaust air of other equipment. Ensure adequate
clearance around the sides of the chassis so that cooling air can flow through the chassis interior unimpeded
and exhaust air exits the chassis and is not drawn into the inlet vent of another device.
Caution
Cisco ASR1001-X Router Alarm Monitoring
The Cisco ASR 1001-X Router displays the CRIT, MAJ, and MIN alarm indicator LEDs. The three system
alarm LEDs on the Cisco ASR 1001-X Router provide visual alarm notification in the router. These LEDs
indicate router status at all times, but you must directly observe these LEDs to become aware of a router alarm
condition. Additionally, you can use the show facility-alarm status command to view the alarms.
Router# show facility-alarm status
System Totals Critical: 4 Major: 0 Minor: 0
Source Time Severity Description [Index]
------ ------ -------- -------------------
Power Supply Module 1 Mar 12 2014 09:05:21 CRITICAL Power Supply Failure [0]
xcvr container 0/0/0 Mar 12 2014 09:05:42 CRITICAL Transceiver Missing - Link
Down [1]
xcvr container 0/0/1 Mar 12 2014 09:05:42 INFO Transceiver Missing [0]
xcvr container 0/0/2 Mar 12 2014 09:05:42 CRITICAL Transceiver Missing - Link
Down [1]
xcvr container 0/0/3 Mar 12 2014 09:05:42 CRITICAL Transceiver Missing - Link
Down [1]
xcvr container 0/0/4 Mar 12 2014 09:05:42 INFO Transceiver Missing [0]
xcvr container 0/0/5 Mar 12 2014 09:05:42 INFO Transceiver Missing [0]
Cisco ASR 1001-X Router Hardware Installation Guide
63
Cisco ASR 1001-X Router Power Up and Initial Configuration
Environmental Monitoring and Reporting Functions

Table of Contents

Other manuals for Cisco ASR 1001-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 1001-X and is the answer not in the manual?

Cisco ASR 1001-X Specifications

General IconGeneral
Product colorGray
Rack capacity1U
Rack mountingYes
Networking standards-
Ethernet LAN (RJ-45) ports6
Installed SFP modules quantity2
Flash memory1024 MB
Internal memory8192 MB
Processor cores4
AC input voltage85 - 264 V
Power source typeAC
Power consumption (typical)250 W
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)5 - 90 %
Security algorithmsAES
Weight and Dimensions IconWeight and Dimensions
Depth461.5 mm
Width439.42 mm
Height43.43 mm
Weight10590 g