Power supply shutdownThe power supply detected an internal out-of-tolerance overvoltage, overcurrent,
or temperature condition and shut itself down. All DC power remains disabled until you toggle the power
switch.
The Cisco ASR 1001-X Router does not shut down automatically during an over-temperature condition. The
router will remain active irrespective of what the ambient temperature is, if the router is exposed to an extremely
hot environment for a prolonged period of time, it will remain active until the hardware fails.
The facility-alarm critical exceed-action shutdown command is disabled on the Cisco ASR 1001-X Router.
The console terminal displays the following error message if you execute the facility-alarm critical
exceed-action shutdown command:
Router(config)# facility-alarm critical exceed-action shutdown
Router(config)# end
Router#
*Apr 22 15:27:26.939: %CMANRPCHAIN-6-NOSHUTWARN: Shutdown not supported on this platform
*Apr 22 15:27:27.974: %SYS-5-CONFIG_I: Configured from console by console
Router#
If the air temperature exceeds a defined threshold, the system controller displays the following warning
message on the console terminal:
Router#
*Apr 22 15:30:37.749: %CMRP_ENVMON-3-TEMP_WARN_CRITICAL: R0/0: cmand: WARNING:
Temp: Inlet temperature sensor on R0 is in a critical state reading 81
Router#
The console terminal displays the following status if you execute the show facility-alarm status command:
Router# show facility-alarm status
System Totals Critical: 2 Major: 0 Minor: 0
Source Time Severity Description [Index]
------ ------ -------- -------------------
xcvr container 0/0/1 Apr 22 2014 15:25:57 CRITICAL Transceiver Missing - Link Down [1]
Temp: Inlet R0/30 Apr 22 2014 15:30:37 CRITICAL Temp Above Normal (Shutdown) [1]
GigabitEthernet0 Apr 22 2014 15:25:42 INFO Physical Port Administrative State Down [2]
Router#
Fan Failures
Four internal fans draw cooling air into the chassis and across internal components to maintain an acceptable
operating temperature. The fans are located in the center of the chassis. The fans are numbered from 0 to 3,
right to left. When the system power is on, all fans should be operational. However, the system continues to
operate even if a fan fails.
Use the show platform hardware slot <slot> fan status command to view the status of the fans, for example:
Router# show platform hardware slot P2 fan status
Cisco ASR 1001-X Router Hardware Installation Guide
65
Cisco ASR 1001-X Router Power Up and Initial Configuration
Fan Failures

Table of Contents

Other manuals for Cisco ASR 1001-X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 1001-X and is the answer not in the manual?

Cisco ASR 1001-X Specifications

General IconGeneral
Product colorGray
Rack capacity1U
Rack mountingYes
Networking standards-
Ethernet LAN (RJ-45) ports6
Installed SFP modules quantity2
Flash memory1024 MB
Internal memory8192 MB
Processor cores4
AC input voltage85 - 264 V
Power source typeAC
Power consumption (typical)250 W
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)5 - 90 %
Security algorithmsAES
Weight and Dimensions IconWeight and Dimensions
Depth461.5 mm
Width439.42 mm
Height43.43 mm
Weight10590 g